Logo franklin-france

The global approach to lightning

Surge Protective Devices for coaxial networks

50 Ohms Coaxstop - N and DIN 7/16 connectors

Description
Coaxstops® are designed for protecting UHF data transmission equipment connected to coaxial networks against natural (lightning) and non natural surge voltages.
The induced discharge currents are deviated to the earth and therefore will not reach the equipment. Equipped with spark gap capsules, these protections are designed for wide bandwidth applications. They allow to transfer DC voltages to the equipment within the limit of the DC spark over voltage (or static ignition (...) read more

50 Ohms Coaxstops - BNC and TNC connectors

Description
Coaxstops® are designed for protecting UHF data transmission equipment connected to coaxial networks against natural (lightning) and non natural surge voltages. Equipped with spark gap capsules, these protections are designed for wide bandwidth applications. Toute décharge de type foudre ou autres transitoires du réseau sont court-circuités dès que la tension de la ligne s’élève à une valeur supérieure à la tension d’amorçage dynamique de l’éclateur ou que la tension continue est (...) read more

Quarter Wave Coaxstop - N and DIN 7/16 connectors

Description
QUARTER WAVE Coaxstops® are designed for protecting UHF data transmission equipment connected to coaxial networks against surge voltages. These protections based on l/4 shorting stubs are especially designed for equipment working at ultra high frequencies in very narrow bandwidths and with very high requirements. Any signal with frequencies lower than 1 MHz being filtered, induced discharge currents are filtered and deviated to the earth. This implies that no DC voltage can be (...) read more

75 Ohms Coaxstop

Description
Coaxstops® are designed for protecting UHF data transmission equipment connected to coaxial networks against natural (lightning)and non natural surge voltages. The induced discharge currents are deviated to the earth and therefore will not reach the equipment. Equipped with spark gap capsules, these protections are designed for wide bandwidth applications.They allow to transfer DC voltages to the equipment within the limit of the DC spark over voltage (or static ignition (...) read more

Franklin France, A subsidiary of theSicame group
13 rue Louis Armand -B.P. 106 | 77834 Ozoir la Ferrière - FRANCE | Tel. : 33 (0)1 60 34 54 44 - Fax : 33 (0)1 64 40 35 43

Le studio vert | Website conforms to the standards of W3C W3C : XHTML 1.0 - CSSlegal notice