The global approach to lightning

Surge protective devices for energy networks

Energy networks

Comply with NF C 15-100, IEC 60364, UTE C 15-443, NF C 61-740 and IEC 61-643-1 standards
Concerns
Interference and discharges of atmospheric origin (lightning induced surges and electrostatic discharges) can create very strong electromagnetic radiation over large distances which can destroy all equipment connected to any nearby power lines. (Highly energetic discharges with long duration times, overvoltages larger than the component’s damage threshold voltage of electronic equipment, (...) read more

Electric networks - Class I modular surge protective devices - T1-25 range

25 kA and 100 kA (10/350) modular protections
120/208 V and 230/400 V networks - Level I Applications
Standards : EN 61643-11 (NF C 61-740, VDE 0675, IEC 61643-1 /2002), UL 1449 ed. 2, ANSI C62.41, EN 61000-4-4, EN 61000-4-5
Description
These products are based on very high energy varistors and encapsulated spark gaps, these surge protective devices are designed for protecting the inputs of main power supplies for highly exposed sites. Their flow capacities are much higher than the (...) read more

Electric networks - Class I and II modular surge protective devices - T1-12.5 range

12,5 kA (10/350) modular protections
120/208 V and 230/400 V networks – Level I and II Applications
Standards : EN 61643-11 (NF C 61-740, VDE 0675, IEC 61643-1 /2002), UL 1449 ed. 2, ANSI C62.41, EN 61000-4-4, EN 61000-4-5
Description
These products are based on very high energy varistors and encapsulated sparkgaps, these surge protective devices are dedicated to the protection of the inputs of highly exposed sites. They fully comply with the minimum requirements of NF C 15-100 and (...) read more

Electric networks - Class II modular surge protective devices - T2-C 1D range

60 and 40 kA (8/20) pre-assembled plug-in protections
120/208 V and 230/400 V networks- Level I and II applications
Standards : EN 61643-11 (NF C 61-740, VDE 0675, IEC 61643-1 /2002), UL 1449 ed. 2, ANSI C62.41, EN 61000-4-4, EN 61000-4-5
Description
These plug-in devices make maintenance of networks (isolation tests or else) very easy and in total security while insuring continuous servicing.
They are pre-assembled in 2,3 and 4 poles with a single remote monitoring terminal (RM) (...) read more

Electric networks - Class II modular surge protective devices - T2-C 2D range

40 kA pre-assembled plug-in protections- TT and TNS systems
120/208 V and 230/400 V networks- Level I, II and III applications
Standards : EN 61643-11 (NF C 61-740, VDE 0675, IEC 61643-1 /2002), UL 1449 ed. 2, ANSI C62.41, EN 61000-4-4, EN 61000-4-5
Description
These devices with a type 2 connexion or "C2" (varistor + sparkgap)1 are recommended for TT and TNS systems. Plugable and pre-assembled in 2 and 4 poles with a single terminal for remote monitoring (RM), their installation is (...) read more

Electric networks - Class II and III modular surge protective devices - T2-M range

40 kA and 10 kA monoblock protections
120/208 V and 230/400 V networks - Level II and III applications
Standards : EN 61643-11 (NF C 61-740, VDE 0675, IEC 61643-1 /2002), UL 1449 ed. 2, ANSI C62.41, EN 61000-4-4, EN 61000-4-5
Description
These devices are recommended for second and third protection stages of energy networks with TT and TNS earthing systems (ASS1108A2 : any earthing system).
Standard applications with 40 kA protections : Main boards of secondary buildings (sites with (...) read more

Main power supplies - Transient overvoltages

VE range
Modular cabinets - 120/208 V and 230/400 V networks
Protection from 10 to 120 kA (8/20) and 10 to 50 kA (10/350)
Standards : EN 61643-11, IEC 61643-1, IEC 60364 and NFC 15-100
Modular cabinets adapted to your needs
Description
These cabinets are designed for Main Boards (MB) and Distribution Boards (DB) overvoltages protection and may be installed in either outdoor or indoor locations including isolated sites.
The concept developed here grants these products a great (...) read more

Overvoltage counter

Description
The overvoltage counter is intended for detecting and recording surge currents on any installations equipped with overvoltage protection systems (surge currents with atmospheric origins such as lightning strikes, interference produced on the mains ...). Designed for DIN foot systems, it is installed in serial on the path of the discharge current towards the earthing system, i.e on the earth conductor in serial in between the overvoltage protection device and earth system.
The (...) read more

Coordination coils and filters

Coordination coils and filters - 230/400 V 
Comply with IEC 60364 and EN 138000 standards.
Description
Overvoltage protection of mains may need in the case of specific applications the arrangement in cascade of multiple levels of surge protective devices. It will then be essential to make these devices compatible together. The device compatibility is of critical interest when these have to be integrated in the same cabinet making the length of the cables interconnecting consecutive (...) read more